CARACTERIZAÇÃO MICROBIOLÓGICA E FÍSICO-QUÍMICA DO LODO DE DECANTADORES DAS ESTAÇÕES DE TRATAMENTO DE ÁGUA APÓS DESAGUAMENTO EM LEITO DE DRENAGEM COM MANTA GEOTÊXTIL

Autores

  • Tatiane das Neves Burgos
  • Emilia Kiyomi Kuroda
  • Cristiane Silveira
  • Paulo Alfonso Schuroff
  • Nicole Ribeiro de Lima
  • Angélica Marim Lopes
  • Jacinta Sanchez Pelayo

DOI:

https://doi.org/10.18764/

Palavras-chave:

Estação de tratamento de água, lodo, Microrganismos, Parâmetros físico-químicos, Tratamento do lodo

Resumo

Nas estações de  tratamento de água  (ETas) o principal  resíduo é o  lodo de decantadores, que pode apresentar
microrganismos e metais tóxicos. foi avaliado o tratamento de lodos provenientes de duas ETas de londrina-Pr (Tibagi e Cafezal) pelo sistema de desaguamento em leito de drenagem com manta geotêxtil. No lodo e nos produtos do desaguamento de lodos: água drenada e a torta (sólidos retidos na manta), foram pesquisados os indicadores microbiológicos coliformes totais  e Escherichia  coli,  além  de Enterococcus  faecalis, E.  faecium,  e Clostridium  perfringens. No  lodo  e  no  drenado foram pesquisados os parâmetros físico-químicos, tais como, metais, demanda Bioquímica de oxigênio (dBo), demanda Química de oxigênio (dQo), turbidez, Ph e cor aparente. os resultados demonstraram a ausência do indicador C. perfringens e  elevados  índices microbiológicos no  lodo  in natura. após o desaguamento  foi observado na ETa Tibagi uma  redução de  95%  dos  indicadores  encontrados  e  79%  na  ETa Cafezal. Nos  parâmetros  físico-químicos  a  redução  foi  de  89%  e 58%,respectivamente, nas duas ETas. Na torta após a exposição à luz solar por 5 dias em ambiente natural, na ETa Tibagi C. perfringens não foi  identifcado, Enterococcus não apresentou redução e nos outros  indicadores a redução foi 99.99%. Na ETa Cafezal C. perfringens não foi  identifcado, e a redução mínima foi de 47.83% para os  indicadores encontrados. Foi evidenciado o potencial poluente do despejo in natura deste resíduo, a necessidade e viabilidade do tratamento do lodo, visando à proteção dos corpos receptores e a saúde da população.

Descritores: Estação de tratamento de água. lodo. Microrganismos. Parâmetros físico-químicos. Tratamento do lodo.

Abstract

in water treatment plants (WTP) the main residue is the sludge found in decanters which may have microorganisms
and toxic metals. The treatment of sludgefrom two WTP of londrina-Pr (Tibagi and Cafezal) was evaluated by dewatering system in drainage bed with geotextile blanket. in the sludge and sludge dewatering products: water drained and the cake (solids retained in the geotextile blanket) were surveyed the microbiological indicators total coliforms and Escherichia coli, besides Enterococcus  faecalis, E.  faecium,  and Clostridium  perfringens.  in  the  sludge  and  drained were  researched  the physical and chemical parameters such as, metals, biochemical oxygen demand (Bod), chemical oxygen demand (Cod), turbidity, ph and apparent color. The results showed the absence of the indicator C. perfringens and high microbiological indices  in  the  in naturasludge. after dewatering was observed  in Tibagi WTP a reduction of 95% of  the  indicators found
and of 79% in Cafezal WTP. in the physical and chemical parameters the reductionwas 89% and 58%, respectively, in both WTP. In relation  to cake, after exposure to sunlight for fve days in a natural environment, C. perfringens was not identifed, Enterococcus did not decrease and other indicators the reduction was 99.99%, inTibagi WTP. in Cafezal WTP,C. perfringens was not identifed and the minimal reduction was of 47.83% for the indicators found. It was shown the polluting potential of in natura discharge of this residue, the need and feasibility of sludge treatment, in order to protect the receiving bodies and the health of population.

Descriptors: Water treatment plants. Sludge. Microorganisms. Physical and chemical parameters. Sludge treatment.

Downloads

Não há dados estatísticos.

Biografia do Autor

Tatiane das Neves Burgos

Laboratório de Bacteriologia da Universidade Estadual de Londrina.

Emilia Kiyomi Kuroda

Laboratório de Hidráulica e Saneamento da Universidade Estadual de Londrina.

Cristiane Silveira

Laboratório de Hidráulica e Saneamento da Universidade Estadual de Londrina.

Paulo Alfonso Schuroff

Laboratório de Bacteriologia da Universidade Estadual de Londrina.

Nicole Ribeiro de Lima

Laboratório de Bacteriologia da Universidade Estadual de Londrina.

Jacinta Sanchez Pelayo

Laboratório de Bacteriologia da Universidade Estadual de Londrina.

Downloads

Como Citar

Burgos, T. das N., Kuroda, E. K., Silveira, C., Schuroff, P. A., Lima, N. R. de, Lopes, A. M., & Pelayo, J. S. (2016). CARACTERIZAÇÃO MICROBIOLÓGICA E FÍSICO-QUÍMICA DO LODO DE DECANTADORES DAS ESTAÇÕES DE TRATAMENTO DE ÁGUA APÓS DESAGUAMENTO EM LEITO DE DRENAGEM COM MANTA GEOTÊXTIL. Revista De Ciências Da Saúde, 17(1), 17–24. https://doi.org/10.18764/

Edição

Seção

Artigos